![]() They shall be free of dust, solvent, paint, wax, oil, grease, residual adhesive, adhesive removers, curing, sealing, hardening/parting compounds, alkaline salts, excessive carbonation/laitance, mold, mildew, and other foreign materials that might prevent the adhesive from bonding. Note: All substrates to receive resilient flooring shall be dry, clean, smooth and structurally sound. Do not stack pallet’s 2 high unless utilizing a 1” thick plywood in between pallets.A 5/8” or thicker plywood must also be placed on the pallet f irst. Then quarter turned for 2 rows side by side, not to exceed 12 boxes high. When palletizing on a jobsite vinyl plank or tiles need to be stacked 2 rows high side by side with no airspace between.away from vents, direct sunlight, etc.) Storing cartons in direct sunlight may affect proper acclimation by inducing thermal expansion/contraction. Preferably, locate material in the “center” of the installation area (i.e. Store cartons of tile or plank products flat and squarely on top of one another.Flooring material and adhesive must be acclimated to the installation area for a minimum of 48 hours prior to installation. ![]() If material from more than one batch is to be used, the job should be laid out so that different batch numbers are not installed side by side. When more than one roll of a color is being installed, all material should be from the same batch and the rolls must be installed in consecutive order.Store all rolls standing upright DO NOT lay rolls for long periods Perform Bond testing to determine compatibility of adhesive to the substrate.Any material installed with visual defects will not be considered a legitimate claim as it pertains to labor cost. Material should always be visually inspected prior to installations. ![]() It is recommended that resilient floor covering installation shall not begin until all other trades are completed.QuikFill is a 2-part urethane treatment that prevents future damage from moisture penetrating to the surface of the slab that may damage or breakdown adhesives or unapproved patching compounds. For cracks or saw cuts deeper than 1", follow the preparation and application instructions for Shaw QuikFill. ![]() Use of gypsum-based patching and/or leveling compounds which contain Portland or high alumina cement and meet or exceed the compressive strength of 3,000 psi are acceptable.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |